BPJSB - HYDROGEN CHLORIDE

Product Identification

Product ID:HYDROGEN CHLORIDE
MSDS Date:10/01/1986
FSC:6830
NIIN:00N030950
MSDS Number: BPJSB

Responsible Party
AIR PRODUCTS & CHEMICALS INC
7201 HAMILTON BLVD
ALLENTOWN, PA 18195
US

Emergency Phone: 800-322-9092;800-523-9374

Info Phone: 215-481-8257

Cage: 00742

Contractor
AIR PRODUCTS AND CHEMICALS INC
ALLENTOWN, PA 18195-1501 US

Telephone: 800-345-3148/ 800-752-1597

Cage: 00742

Ingredients

HYDROCHLORIC ACID;(HYDROGEN CHLORIDE) (SARA III)

CAS: 7647-01-0

RTECS: MW4025000

OSHA PEL 5 PPM,C

ACGIH TLV: 5 PPM,C

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


CALL MD IMMEDIATELY .

RTECS: 9999999ZZ


HCL BURNS & SKIN LESIONS RSLTG IN TISS

RTECS: 9999999ZZ


RSLT FROM EXPOS TO LOWER RESP TRACT & DEEP LUNG.

RTECS: 9999999ZZ


EYE RESULT IN LESIONS AND POSSIBLE LOSS OF VISION.

RTECS: 9999999ZZ


CLSD, OUTLET SEALS SECURED & VALVE PROT CAP

RTECS: 9999999ZZ


GAS CYLS SHOULD NOT BE REFILLED EXCEPT BY

RTECS: 9999999ZZ


COMPRESSED GAS CYL WHICH HAS NOT BEEN FILLED BY OWNER

RTECS: 9999999ZZ


(49 CFR).PROT CYL FROM PHYS DMG. DO NOT

RTECS: 9999999ZZ


VALVE PROT CAPS MUST REMAIN IN PLACE UNLESS CNTNR IS

RTECS: 9999999ZZ


REDUCING REGULATOR WHEN CONNECTING CYL TO LOWER

RTECS: 9999999ZZ


DISCHARGE RATE. USE CHECK VALVE/TRAP IN DISCHARGE

RTECS: 9999999ZZ


CONSULT MFRS SPECIALTY GAS CATALOGUE/COMPRESSED GAS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE & IRRIT TO UPPER/LOWER RESP
TRACTS, SKIN & EYES. IT HYDROLYZES VERY RAPIDLY YIELDING
HYDROCHLORIC ACID. SKIN BURNS & MUCOSAL IRRIT ARE LIKE THAT FROM
EXPOS TO VOLAT INORGANIC ACIDS. SYMPS IN CL TEARING, COUGHING,
LABORED BRTHG & EXCESS SALIVARY & SPUTUM FORMATION. EXCESSIVE IRRIT
OF LUNGS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CAUSES ACUTE PNEUMONITIS (DEEP LUNG
INFLAMMATION) & PULM EDEMA (ABNORMAL FLUID BUILDUP IN LUNGS) WHICH
COULD BE FATAL. HYDROCHLORIC ACID BURNS EXHIBIT SEVERE PAIN,
REDNESS, POSS SWELLING & TI SS DESTRUCTION. HYDROGEN CHLORIDE IS
IRRIT/CORROSIVE TO ALL LIVING TISS. TOX LEVEL EXPOS TO SKIN TISS
CAUSES (ING 4)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:IMMED MEDICAL ATTN REQ IN ALL CASES OF OVEREXP TO HYDROGEN
CHLORIDE. RESCUE PERS SHOULD BE EQUIPPED W/APPROP PROT EQUIP (SCBA,
ETC.) TO PVNT UNNEC EXPOS. INHAL:MOVE TO UNCONTAM AREA. IF NOT
BRTHG GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF BRTHG DFCLT, GIVE
O2. KEEP WARM/QUIET. ASSURE MUCUS/VOMITED MATL DOES NOT OBSTRUCT
AIRWAY BY USE OF POSITIONAL DRAINAGE. DELAYED PULM EDEMA MAY OCCUR.
(SUPP DATA)

Fire Fighting

Extinguishing Media:NONFLAMMBLE. USE MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
EQUIP . IF POSS, W/OUT RISK, MOVE CYLS FROM FIRE AREA. KEEP CYLS
COOL W/WATER SPRAY FROM DISTANCE UNTIL (SUPDAT)
Unusual Fire/Explosion Hazard:CYLINDERS MAY VENT RAPIDLY OR EXPLODE
WHEN EXPOSED TO FIRE OR INTENSE HEAT.

Accidental Release

Spill Release Procedures:EVACUATE ALL PERSONNEL FROM AFFECTED AREA. USE
APPROPRIATE PROTECTIVE EQUIPMENT. IF LEAK IN USER'S EQUIPMENT, BE
CERTAIN TO PURGE PIPING W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF
LEAK IS IN CNTNR/CN TNR VALVE, CALL "800" EMERG PHONE # LISTED
HEREIN.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY, WELL-VENT AREA
AWAY FROM HEAVILY TRAVELED AREAS & EMERG EXITS. DO NOT ALLOW TEMP
WHERE CYLS ARE STORED TO EXCEED 125F (51.7C).
Other Precautions:CYLS SHOULD BE STORED UPRIGHT & FIRMLY SECURED TO
PVNT FALLING OR BEING KNOCKED OVER. FULL/EMPTY CYLS SHOULD BE
SEGRAGATED. USE "FIRST IN-FIRST OUT" INVENTORY SYS TO PVNT FULL
CYLS BEING STORED FOR EX CESS PERIODS OF TIME. COMPRESSED (ING 8)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE
WITH MASK OR SCBA SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:HOOD W/FORCED VENTILATION. LOCAL EXHAUST:TO PREVENT
ACCUMULATION ABOVE THE CEILING LIMIT FOR HCL.
Protective Gloves:PLASTIC OR RUBBER GLOVES.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FSHLD .
Other Protective Equipment:SAFETY SHOES, SAFETY SHOWER, EYEWASH
"FOUNTAIN", PLASTIC OR RUBBER SUIT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VP:612.1 PSIA @ 70F. FIRE FIGHT PROC:WELL AFTER FIRE IS OUT. RUNOFF
FROM FIRE CNTRL MAY CAUSE POLLUTION. FIRST AID PROC:KEEP PATIENT
UNDER MEDICAL OBSERVATION FOR AT LEAST 24 HOURS. EYE:PERS W/POTNTL
EXPOS TO HCL SHOULD NOT WEAR CNTCT LENSES. FLUSH CONTAM EYE(S) W/
LRG QTYS OF WATER FOR AT LEAST 15 MINS. HOLD (ING 2)

Chemical Properties

HCC:C1
Boiling Pt:B.P. Text:-121F,-85C
Vapor Pres:SUPP DATA
Spec Gravity:1.27@70F(AIR=1)
Solubility in Water:VERY SOLUBLE
Appearance and Odor:COLORLESS GAS WITH A SHARP, PUNGENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
WATER, ORGANIC MATERIALS, FLUORINE, CALCIUM CARBIDE, CESIUM CARBIDE,
RUBIDIUM CARBIDE, LITHIUM SILICIDE, MOST METALS.
Stability Condition to Avoid:MOISTURE IN PROCESS SYSTEM.
Hazardous Decomposition Products:HYDORCHLORIC ACID ON HYDROLYSIS.
HYDROGEN GAS IN REACTION WITH MOST METALS.

Disposal

Waste Disposal Methods:ALL FED, STATE & LOC REGS REGARDING HLTH &
POLLUTION SHOULD BE FOLLOWED IN WASTE DISP. CNTCT AIR PRODUCTS FOR
SPECIFIC REC. DO NOT DISPOSE OF UNUSED QTYS. RETURN PROPERLY
LABELED SHIPPING CNTNR TO AIR PRODUCTS FOR DISP W/VALVE(S) TIGHTLY
(ING 7)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.